APC NetShelter Rack PDU Advanced, Switched, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 42 Outlets, IEC309

SKU
APDU10250SW
£1,862.64 £1,552.20
In stock
Only 2 left
NetShelter Rack PDU Advanced, Switched, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 42 Outlets, IEC309
  • Switched, 11.5kW, 3PH
  • 415V, 20A, 520P6
  • 42 Outlet
  • Power metering via remote access
  • High Density
  • Availability
  • Agility
  • Manageability
More Information
AC outlets quantity 42 AC outlet(s)
SKU APDU10250SW
EAN 0731304439691
Manufacturer APC
Availability In Stock
PDF URLs View PDF
View PDF
View PDF
View PDF
View PDF
View PDF
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
Design
On/off switchYes
TypeThree-phase
PDU typesSwitched
MountingVertical
DisplayLCD
Product colourBlack
Form factorRackmount
Regulatory ApprovalsCE, CSA C22.2 No 62368-1, EN 62368-1, FCC part 15 subpart B, UKCA, UL 62368-1
Rack capacity0U
Ports & interfaces
USB ports quantity1
AC outlets quantity42 AC outlet(s)
AC outlet typesC13 coupler, C15 coupler, C19 coupler, C21 coupler
Power plugIEC 60309
Ethernet LAN (RJ-45) ports2
Features
Cable length1.8 m
LED indicatorsActivity, Network, Power
Daisy chainYes
Surge protectionYes
Colour-coded outletsYes
Security algorithms128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3
Password protectionYes
Compatible productsCompatible with most NetShelter SX enclosures and third-party racks
Reset buttonYes
Management features
Firmware upgradeable viaNetwork, USB
Firmware upgradeableYes
MonitoringCurrent, Humidity, Power, Temperature, Voltage
Outlet controlLock-out, Recycle, Turn off, Turn on
Ergonomics
Cable length1.8 m
LED indicatorsActivity, Network, Power
DisplayLCD
Compatible productsCompatible with most NetShelter SX enclosures and third-party racks
Power
Maximum power11500 W
Nominal input voltage400 V
Nominal output voltage230 V
Output voltage230 V
Power protection featuresOverload
Maximum current16 A
Maximum total current draw per phase16 A
Load capacity11500 VA
Surge protectionYes
AC input frequency50 - 60 Hz
Number of phases3
Weight & dimensions
Weight7.2 kg
Width56 mm
Depth75 mm
Height1490 mm
Package width208 mm
Package depth116 mm
Package height1720 mm
Package weight9.2 kg
Packaging data
Package width208 mm
Package depth116 mm
Package height1720 mm
Package weight9.2 kg
Operational conditions
Operating temperature (T-T)-5 - 60 °C
Storage temperature (T-T)-25 - 65 °C
Storage relative humidity (H-H)5 - 95%
Operating relative humidity (H-H)5 - 95%
Operating temperature (T-T)23 - 140 °F
Operating altitude0 - 3048 m
Non-operating altitude0 - 15240 m
Technical details
Total carbon footprint (kg of CO2e)2894.37
Compliance certificatesRoHS
Security
Security algorithms128-bit AES, 192-bit AES, 256-bit AES, DES, MD5, SNMP, SNMPv2, SNMPv3
Password protectionYes

You may also be interested in

Compare Products
Product APC NetShelter Rack PDU Advanced, Switched, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 42 Outlets, IEC309 APC NetShelter Rack PDU Advanced, Swit...
£1,862.64 £1,552.20
APC AP8888 power distribution unit (PDU) 42 AC outlet(s) 0U Black APC AP8888 power distribution unit (PD...
£2,037.42 £1,697.85
APC Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 16A, 230V, (21) C13 & (3) C19 APC Rack PDU 2G, Metered by Outlet wit...
£1,495.12 £1,245.93
APC NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
Bestseller
APC NetShelter Metered Rack PDU, 0U, 3...
£1,905.00 £1,587.50
APC EPDU1232SX3620 power distribution unit (PDU) 36 AC outlet(s) 0U Black APC EPDU1232SX3620 power distribution...
£1,734.77 £1,445.64
Eaton EVMAF132X power distribution unit (PDU) 42 AC outlet(s) 39U Black
New
Eaton EVMAF132X power distribution uni...
£1,608.35 £1,340.29
SKU
APDU10250SW
AP8888
AP8659EU3
AP8886
EPDU1232SX3620
EVMAF132X
Description
APC NetShelter Rack PDU Advanced provide reliable power distribution to IT Equipment within server and/or networking racks. Switched outlets to turn outlets on or off remotely. PDU level power metering via remote access and local display for power visibility and notification of potential overload. 4-in-1 combination outlets which can be used as either C13, C19, C15, or C21 outlets provide unparreled deployment flexibility. Maximum outlet density with 42 outlets in a 2.2 wide form factor. Outlets on the PDUs are color coded and/or labeled by breaker and input phase on 3 phase models to simplify deployment. Provides an alternating phase design whereby each of the 3 phases are organized into small outlet groups which alternate from top to bottom of the PDU to facilitate better power cord management and promote better load balancing. Power Sharing allows PDUs cascaded together via 2 ethernet ports enable an Network Management Card to continue functioning in the event of an AC power loss. No interruption in Network communication, sensors operation, and alarm traps. Live Swap Network Management Card (NMC) which can be replaced without powering down the PDU or connected devices to minimize downtime in the unlikely event of an NMC power event. Rated and approved to operate up to 60C (140F) at full load ensures reliability and availability even in today's high density deployments. Gigabit ethernet to enhance and standardize network connectivity across all assets in the data center. A second ethernet port (10/100) is available to allow cascading to other PDUs, connect to a 2nd private network, or provide network redundancy. 1% metering accuracy for the peace of mind to use NetShelter Rack PDU Advanced to bill based on power usage. In addition, the higher level of accuracy ensures the most precise measures for capacity planning and threshold alarm monitoring. Two environmental sensor ports allow for optional sensors (sold separately) to be connected. For data center deployments across multiple regions, these PDUs are both UL and CE rated providing one PDU that can be used globally to simplify and standardize deployment.
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
APC Metered by Outlet with Switching Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and individual outlet power metering Remote outlet level controls allow power on/off functionality for power recycling to reboot locked-up equipment and to avoid unauthorized use of individual outlets Power sequencing delays allow users to define the order in which to power up or down attached equipment Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding Current metering provides real-time remote monitoring of connected loads Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, and locking IEC receptacles User-defined alarms warn of potential circuit overloads before critical IT failures occur Users can access, configure, and control Switched rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager
APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. The output and input connections are (30) C13 & (12) C19, and the cable length is 1.83m. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Easy Switched Rack Power Distribution Units (Rack PDU) provide on/off outlet switching, advanced power management, load monitoring and much more features than the average power strip.
No
Short Description
NetShelter Rack PDU Advanced, Switched, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 42 Outlets, IEC309
PDU 2G, Metered, ZeroU, 23kW, 240V, 32A, 50/60Hz, 30xC13 & 12xC19, 10.1kg, Black
Rack PDU 2G, Metered by Outlet with Switching, ZeroU, 16A, 230V, (21) C13 & (3) C19
NetShelter Metered Rack PDU, 0U, 3PH, 22kW 230V 32A or 17.3kW 230V 24A, x30 C13 and x12 C19 outlets, IEC 309 3P+N+PE cord
EasyPDU, Switched, Zero U, 22 kW, 230V, 30 x C13 & 6 x C19
Managed G4 Rack PDU, 39U, 7.4 kW, 32 A, 24xC13, 18xC39, 3 m cord
Manufacturer
APC
APC
APC
APC
APC
EATON
Search engine powered by ElasticSuite
Please type the letters and numbers below